STAR LIne Mode Command Specifications
ESC VT m n
[Name] Sets slip paper discharge direction and discharge length
[Code]
ASCII
ESC VT
m
n
Hexadecimal
1B 0B
m
n
Decimal
27
11
m
n
[Defined Area]
Thermal
: -
Slip
: -
Validation
: -
[Initial Value]
Thermal
: -
Slip
: -
Validation
: -
[Function]
Four bytes ignored
ESC EM n m LF NUL
[Name] Set slip/validation automatic clamp
[Code]
ASCII
ESC
EM
n
M LF NUL
Hexadecimal
1B
19
n
M 0A
00
Decimal
27
25
n
M
10
0
[Defined Area]
Thermal
: -
Slip
: 0 ≤ n ≤ 255
m = 0, 1, 48, 49
Validation
: 0 ≤ n ≤ 255
m = 2, 3, 50, 51
[Initial Value]
Thermal
: -
Slip
: n: MSW Setting
m = 0
Validation
: n: MSW Setting
m = 0
[Function]
m
Function
0, 1, 48, 49 Sets the waiting time from inserting slip paper until the start of execution of automatic clamp
according to n.
n is the same as the MSW slip opening time setting (for details refer to the MSW settings for
each printer).
2, 3, 50, 51 Sets the waiting time from inserting validation paper until the start of execution of automatic
clamp according to n.
n is the same as the MSW validation opening time setting (for details refer to the MSW
settings for each printer).
Only setting is valid. Setting is valid after switching to slip or validation.