beautypg.com

Siemens release – Siemens Brodersen MC55 AT User Manual

Page 79

background image

MC55_ATC_V04.00

Page 79 of 475

3/17/06

Confidential / Released

3.4.10

SIEMENS release cause for Call-related Supplementary Ser-
vices (CRSS)

Number

Description

0

ECT procedure failed (timer expired)

1

Call has been cleared without receiving an answer to ECT request

2

Initial conditions not fulfilled (one active, one held call)

3

Received "return error"

4

Call has been cleared without receiving an answer to CCBS request

5

Initial conditions for CCBS not fulfilled (Idle CRSS)

Causes related to nature of request
25

LLC or SNDCP failure

26

Insufficient resources

27

Unknown or missing access point name

28

Unknown PDP address or PDP type

29

User authentification failed

30

Activation rejected by GGSN

31

Activation rejected, unspecified

32

Service option not supported

33

Requested service option not subscribed

34

Service option temporarily out of order

35

NSAPI already used

36

Regular PDP context deactivation

37

QoS not accepted

38

Network failure

39

Reactivation requested

40

Feature not supported

Causes related to invalid messages
81

Invalid transaction identifier value

95

Semantically incorrect message

96

Invalid mandatory information

97

Message type non-existant or not implemented

98

Message type not comaptible with protocol state

99

Information element non-existent or not implemented

100

Conditional information element error

101

Message not compatible with protocol

111

Protocol error, unspecified