9 ath disconnect existing connection, Ath disconnect existing connection – Siemens Brodersen MC55 AT User Manual
Page 136
MC55_ATC_V04.00
Page 136 of 475
3/17/06
Confidential / Released
7.9
ATH Disconnect existing connection
Syntax
Command Description
Disconnect existing call from command line by local TE and terminate call.
Parameter Description
[0]
disconnect from line and terminate call
Notes
• OK is issued after circuit 109 (DCD) is turned off, if it was previously on.
•
terminates every circuit switched call (voice, data or fax), even if it is issued via another interface. This
behavior is in accordance with ITU-T V.250; (07/97, "Hook control": "
is terminating any call in progress.").
•
clears any active PDP context or terminates any existing PPP connection, but only if issued on the same
interface where GPRS is used and if there is no pending network request for PDP context activation. It does
not affect PDP contexts and PPP connections on other interfaces (see also Chapter "
Manual rejection
of a network request for PDP context activation").
Exec Command
ATH
]
Response(s)
OK
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
V.250
!
%
%
%
%
%
!
!
!
(num)