Index, S), (list – Siemens Brodersen MC55 AT User Manual
Page 350
MC55_ATC_V04.00
Page 350 of 475
3/17/06
Confidential / Released
2
SMS-DELIVERs, except class 2 messages and messages in the message
waiting indication group (store message) are routed directly to the TE using
unsolicited result code:
3
Class 3 SMS-DELIVERs are routed directly to the TE using unsolicited result
codes defined in
=2. Messages of other data coding schemes result in
=1.
Rules for storing received CBMs depend on the relevant data coding method (refer to GSM 03.38), the setting
of Select CBM Types (
) and this value:
[0]
(&F)
No CBM indications are routed to the TE.
2
New CBMs are routed directly to the TE using unsolicited result code:
3
Class 3 CBMs are routed directly to TE using unsolicited result codes defined
in
=2.
[0]
(&F)
No SMS-STATUS-REPORTs are routed to the TE.
1
SMS-STATUS-REPORTs are routed to the TE using unsolicited result code:
2
If SMS-STATUS-REPORT is routed into ME/TA, indication of the memory
location is routed to the TE using unsolicited result code:
[1]
(&F)
TA buffer of unsolicited result codes defined within this command is cleared
when
changes from 0 to 1...3.
Integer type; value in the range of location numbers supported by the associated memory
Notes
• Parameters
=2,3 and
=1 are only available with GSM phase 2+ (see
=1). Incoming SMs
or Status Reports have to be acknowledged with
=0 when using these phase 2+ parameters.
• Requirements specific to Multiplex mode:
=0) only one channel can use a phase 2+ parameter. The parameter for
and
on the other channels have to be set to zero. If either a SM or a Status Report is not acknowledged,
all
parameter in all channels will be set to zero.
• If the ME operates on different instances (MUX channels 1, 2, 3 or ASC0/ASC1) avoid different settings for
routing and indicating short messages. For example, if messages shall be routed directly to one instance of
the TE (set with
,
), it is not possible to activate the presentation of URCs with
or
on another instance. Any attempt to activate settings that conflict with existing settings on
another interface, will result in CME ERROR, or accordingly CMS ERROR.
• Handling of Class 0 short messages:
If the host application is provided with a display and
=1 has been set Class 0 short messages can
be displayed immediately.
If the host application does not include a display, ME handles Class 0 short messages as though there was
no message class, i.e. it will ignore bits 0 and 1 in the
and normal rules for exceeded memory capacity
shall apply. This approach is compliant with GSM 03.38 .
• The parameters
and
of the
command is set to 1.
• If either a SM or a Status Report is not acknowledged, all
parameter in all channels will be set to
zero.
(num)(&W)(&V)
(num)(&W)(&V)
(num)(&V)
(num)