State, Alphabet, Ssta – Siemens Brodersen MC55 AT User Manual
Page 377: Allowedinstance, Satprofile, Mode
MC55_ATC_V04.00
Page 377 of 475
3/17/06
Confidential / Released
Parameter Description
MC55 Remote-SAT interface states
0
RESET
1
OFF
2
IDLE
3
PAC
4
WAIT
0
GSM character set
Input of a character requests one byte, e.g. "Y".
1
UCS2
To display the 16 bit value of characters represented in UCS2 alphabet a 4 byte
string is required, e.g. "0059" is coding the character "Y". For details please
refer to ISO/IEC 10646.
0
SAT is already used on another instance (logical channel in case of the multi-
plex protocol). Only test and read commands can be used.
1
SAT may be started on this instance via the write version of this command.
SAT profile according to GSM 11.14
The profile tells the SIM Application which features (e.g. proactive commands) are supported by the SIM Appli-
cation Toolkit implementation of the MC55.
1
Activate Remote-SAT
Note
• To limit the time Remote-SAT is kept in states PAC or WAIT any ongoing (but unanswered) Proactive Com-
mand is automatically aborted after 10 minutes with Terminal Response "ME currently unable to process com-
mand" or "No response from user" if applicable. An URC "Terminate Proactive Command" will be send to the
external application in this case, too.
(num)
(num)
(num)
(str)
(num)