Parameter Description
Indicates the state of PDP context activation.
0
deactivated
[1]
activated
PDP Context Identifier is a numeric parameter which specifies a particular PDP context definition. The param-
eter is local to the TE-MT interface and is used in other PDP context related commands.
1...2
Notes
•
will deactivate any PDP context.
• If the MT is in dedicated mode, the write command returns "+CME ERROR: operation temporary not allowed".
• A maximum of 2 contexts can be activated at the same time, no matter on which interface. Trying to activate
more than 2 contexts will cause "+CME ERROR: operation temporary not allowed". Note that, depending on
the provider, the number of activated contexts may be further restricted. In such cases "+CME ERROR:
unspecified GPRS error" will be returned and
returns "+CEER: 50,26,0".
Remember that contexts may be activated implicitly by using the
or
GPRS compatibility
commands without specifying a
• If an activated context will be deactivated without using the command
, then the result code "NO
CARRIER" will be issued to indicate the context deactivation. This happens for example if the context deac-
tivation is forced by the network or if deactivation results from a network deregistration with
=2.
(num)
(num)