7.27

AT^STCD Display Total Call Duration

Syntax

Command Description

TA returns total call duration (accumulated duration of all calls).

Parameter Description

Format is "hh:mm:ss", where characters indicate hours, minutes, seconds; E.g. 22:10:00 "22:10:00"

Max value is 9999:59:59

Notes

• The Total Call Duration will not be reset by power off or other means.
• The proper working of that command is network dependant and only for MO calls.

Test Command

AT^STCD=?

Response(s)

OK

ERROR

+CME ERROR

Exec Command

AT^STCD

Response(s)

^STCD:

OK

ERROR

+CME ERROR