Mode, Inddescr, List o – Siemens Brodersen MC55 AT User Manual
Page 63
MC55_ATC_V04.00
Page 63 of 475
3/17/06
Confidential / Released
String values and their
ranges.
More indications are available via
. Therefore use of
for control of all indications is recom-
mended.
The following indications are accessible via
:
"battchg"
Battery charge level 0..4 or 5 if no measuring is performed, e.g because no bat-
tery is connected. Also refer to
"signal"
Signal quality (0..7) or (99) if not measurable
The indicated value is the bit error rate of the signal received. Bit errors are esti-
mated values. See also
"service"
Service availability (0-1)
0: Not registered to any network
1: Registered to home network or, if "roam"=1 then registered to another net-
work
"sounder"
Sounder activity (0-1)
Reports every event that causes the ME to generate a tone.
Value 1 means for example:
Incoming call - ME is ringing. Note that the URC "
: sounder" will be out-
put only if ringing tones are activated with
Waiting call - ME generates waiting call tone (if call waiting is enabled).
Outgoing call - ME generates Call Progress tone.
Outgoing call - ME generates BUSY tone.
The value changes to 0 when the tone stops.
"message"
Unread short message at memory location
(0-1); refer to
"call"
Call in progress (0-1). Indicator value is "1" if at least one call is in state "active"
or "held".
the indicator
"call" will be issued
• when a state transition ends in state "active" or state "unknown", if
="restricted",
• when any state transition (including transitions beginning or ending in state
"unknown") occurs in the list of active calls or when a traffic channel is
established, if
="verbose".
Also refer to Section
"roam"
Roaming indicator (0-1)
0: Registered to home network or not registered
1: Registered to other network
"smsfull"
A short message memory storage in the MT has become full (1) or memory
locations are available (0), i.e. range is (0-1)
"rssi"
Received signal (field) strength (0..5) or (99) if not measurable
0: signal strength <= -112 dbm
1-4: signal strength in 15 dbm steps
5: signal strength >= -51 dbm
Received signal (field) strength can also be obtained with
. However,
the signal strength is scaled to value range 0..31 by this command.
0
Indicator is deregistered. The indicator will not be presented as "
" URC,
but can be queried with
?.
[1]
(&F)(P)
Indicator is registered, indicator event report allowed.
(str)
(num)