beautypg.com

18 at^slms list sms memory storage – Siemens Brodersen MC55 AT User Manual

Page 360

background image

MC55_ATC_V04.00

Page 360 of 475

3/17/06

Confidential / Released

13.18

AT^SLMS List SMS Memory Storage

AT^SLMS

indicates the max. capacity of each SMS storage type and the number of locations currently used.

Syntax

Parameter Description

Maximum number of messages storable in the SMS memory of the SIM (physical storage "SM")

Maximum number of messages storable in the SMS memory of the Mobile Equipment (physical storage "ME")

Sum of "SM" and "ME", indicated as "MT". Maximum number of all messages storable in the SIM memory and

the Mobile Equipment memory.

Number of messages currently stored in the SMS memory of the SIM (physical storage "SM")

Number of messages currently stored in the SMS memory of the Mobile Equipment (physical storage "ME")

Concatenated logical SMS storages of SIM ("SM") and Mobile Equipment ("ME"). Sum of all messages currently

stored, indicated as "MT".

Note

• Users should be aware that when using this AT command quickly after SIM PIN authentication the SIM data

may not yet be accessible, resulting in a short delay before the requested AT command response is returned.

See Section

20.1

,

Restricted access to SIM data after SIM PIN authentication

for further detail.

Test Command

AT^SLMS=?

Response(s)

OK

Exec Command

AT^SLMS

Response(s)

^SLMS:

''MT'',

,

^SLMS:

''SM'',

,

^SLMS:

''ME'',

,

OK

ERROR

+CMS ERROR

Reference(s)

PIN

ASC0 ASC1

MUX1

MUX2

MUX3 Charge

Last

SIEMENS

%

%

%

%

%

%

!

!

!

(num)

(num)

(num)

(num)

(num)

(num)