18 at^slms list sms memory storage – Siemens Brodersen MC55 AT User Manual
Page 360
MC55_ATC_V04.00
Page 360 of 475
3/17/06
Confidential / Released
13.18
AT^SLMS List SMS Memory Storage
indicates the max. capacity of each SMS storage type and the number of locations currently used.
Syntax
Parameter Description
Maximum number of messages storable in the SMS memory of the SIM (physical storage "SM")
Maximum number of messages storable in the SMS memory of the Mobile Equipment (physical storage "ME")
Sum of "SM" and "ME", indicated as "MT". Maximum number of all messages storable in the SIM memory and
the Mobile Equipment memory.
Number of messages currently stored in the SMS memory of the SIM (physical storage "SM")
Number of messages currently stored in the SMS memory of the Mobile Equipment (physical storage "ME")
Concatenated logical SMS storages of SIM ("SM") and Mobile Equipment ("ME"). Sum of all messages currently
stored, indicated as "MT".
Note
• Users should be aware that when using this AT command quickly after SIM PIN authentication the SIM data
may not yet be accessible, resulting in a short delay before the requested AT command response is returned.
See Section
Restricted access to SIM data after SIM PIN authentication
for further detail.
Test Command
AT^SLMS=?
Response(s)
OK
Exec Command
AT^SLMS
Response(s)
^SLMS:
,
^SLMS:
''SM'',
^SLMS:
''ME'',
OK
ERROR
+CMS ERROR
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
SIEMENS
%
%
%
%
%
%
!
!
!
(num)
(num)
(num)
(num)
(num)
(num)