At^snfm – Siemens Brodersen MC55 AT User Manual
Page 413
MC55_ATC_V04.00
Page 413 of 475
3/17/06
Confidential / Released
17.12
AT^SNFM Set microphone audio path and power supply
The
read command returns the microphone mute and supply voltage status.
The
write command can be used to switch the microphone's audio path (muted / not muted) or to con-
trol the power supply of the MICP2 line (microphone input of the second analog audio interface).
The microphone can be muted or activated by changing
in all audio modes (1 to 6) and during a
voice call only. As an alternative, you can use the
command to mute the microphone.
Syntax
Parameter Description
Microphone mute control parameter.
Evaluated only during voice calls and if
is omitted, e.g.
=1.
Command does not depend on audio mode.
0
Mutes the microphone.
1
(P)
Activates the microphone.
Microphone supply voltage control parameter. Setting applies to microphone input 2 only.
CME error is given if
is not omitted. Enter for example
=,2.
0
Supply voltage is always switched off.
1
Supply voltage is always switched on.
2
(P)
Supply voltage state during voice calls is controlled by the ME. Actual value is
determined by parameter data set of the selected audio mode.
Test Command
AT^SNFM=?
Response(s)
^SNFM:
(list of supported
s) , (list of supported
s)
OK
Read Command
AT^SNFM?
Response(s)
OK
Write Command
AT^SNFM=
][,
Response(s)
OK
ERROR
Reference(s)
PIN
ASC0 ASC1
MUX1
MUX2
MUX3 Charge
Last
SIEMENS
!
%
%
%
%
%
!
!
!
(num)
(num)