MC55_ATC_V04.00

Page 247 of 475

3/17/06

Confidential / Released

^SISR: 0,1

Service profile 0 is configured for Socket service and UDP. The URC

notifies host that data is available for reading.

at^sisr=0,6

The host requests to read 6 bytes.

^SISR: 0,6,12
THIS_I

The first 6 bytes of datagram A are confirmed and transmitted. Another

12 bytes are still available.

OK

at^sisr=0,6

The host requests to read the next part of 6 bytes.

^SISR: 0,6,6
S_DATA

The next 6 bytes of datagram A are confirmed and transmitted. Another

6 bytes are still available.

OK

at^sisr=0,6

The host requests to read the next part of 6 bytes.

^SISR: 0,6,0
GRAM_A

Last part of datagram A was received, no remainder is left.

OK

at^sisr=0,6

Again, the host requests to read 6 bytes. This time, the request refers to

datagram B which has only 3 bytes. As the read datagram is smaller

than the size requested by the host, the response does not include the

.

^SISR: 0,3
NEW

3 bytes are confirmed and transmitted. Datagram B was properly

received.

OK