Unsolicited Result Codes

URC 1

+CALA: [

]

Indicates reminder message.

URC 2

^SYSSTART ALARM MODE
+CALA:

Indicates ME wake-up into Alarm mode. If autobauding is active (

AT+IPR

=0) the line "

+CALA

" does not

appear, but your individual

message will be displayed.

Parameter Description

Format is "yy/MM/dd,hh:mm:ss". For example, 6th of July 2005, 22:10:00 equals to "05/07/06,22:10:00" (see

also

AT+CCLK

).

Note: If

equals current date and time or is set to an earlier date, TA returns +CME ERROR: 21.

Integer type value indicating the array index of the alarm.

The ME allows to set only one alarm at a time. Therefore, the list of supported alarm events indicated by the test

command

AT+CALA

=? is

=0. If a second alarm time is set, the previous alarm will be deleted. Therefore, the

read command

AT+CALA

? will always return

=0. This is also true if individual settings are made on ASC0

and ASC1 or the various Multiplexer channels, for details see notes below.

Integer type value indicating the type of the alarm.
0

Alarm indication: text message via serial interface

String type value indicating the text to be displayed when alarm time is reached; maximum length is

.

By factory default,

is undefined.

Note:

will be stored to the non-volatile flash memory when the device enters the Power Down mode via

AT^SMSO

. Once saved, it will be available upon next power-up, until you overwrite it by typing another text. This

eliminates the need to enter the full string when setting a fresh alarm.

should not contain characters which are coded differently in ASCII and GSM (e.g. umlauts), see also

"Supported character sets" and "GSM alphabet tables".

Integer type value indicating the maximum length of

. The maximum length is 16.

Notes

• After the alarm was executed the parameter

of

AT+CALA

will be reset to "00/01/01,00:00:00", but

will be preserved as described above.

• If MC55 is totally disconnected from power supply the most recently saved configuration of +CALA:

[,

[,

[,

]]] will be presented when MC55 is powered up.

• Each time MC55 is restarted with ignition it takes 2s to re-initialize the RTC and to update the current time.

Therefore, it is recommended to wait 2s before using the commands

AT+CCLK

and

AT+CALA

(for example

2s after ^SYSSTART has been output).

(str)

(num)

(num)

(str)

(num)