beautypg.com

17 +++ switch from data mode to command mode, With, The p – Siemens Brodersen MC55 AT User Manual

Page 144

background image

MC55_ATC_V04.00

Page 144 of 475

3/17/06

Confidential / Released

7.17

+++ Switch from data mode to command mode

Syntax

Command Description

This command is only available during a CSD call or a GPRS connection. The +++ character sequence causes

the TA to cancel the data flow over the AT interface and switch to command mode. This allows you to enter AT

commands while maintaining the data connection to the remote device or, accordingly, the GPRS connection.

To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and followed by a

pause of at least 1000 ms. The +++ characters must be entered in quick succession, all within 1000 ms.

Notes

• To return from command mode to data or PPP online mode: Enter

ATO

.

• In Multiplex mode the +++ sequence does not work. Therefore, if required in Multiplex mode, the escape

sequence needs to be implemented in the customer's external Multiplex application. Design solutions, for

example using the DTR signal or a modem status command (MSC), can be found in

[5]

, Section "Escape

Sequence". See also Section

4.8

,

AT+CMUX

.

• On ASC1 the +++ sequence can be used in GPRS connections for switching from PPP online to command

mode.

Exec Command

+++

Response(s)

OK

Reference(s)

PIN

ASC0 ASC1

MUX1

MUX2

MUX3 Charge

Last

V.250

!

%

§

!

!

!

!

!

!