beautypg.com

RIGOL DS6000 Series User Manual

Page 47

background image

1 Quick Start

RIGOL

DS6000 User’s Guide

1-25

2. Channel Label/Waveform

Different channels are marked by different colors and the color of the
waveform complies with the color of the channel.

3. Status

Available states include RUN, STOP, T’D (triggered), WAIT and AUTO.

4. Horizontal Time Base

 Represent the time per grid on the horizontal axis on the screen.
 Use HORIZONTAL

SCALE to modify this parameter. The range

available is from 500 ps to 1.000 ks.

5. Sample Rate/Memory Depth

 Display the current sample rate and memory depth of the oscilloscope.
 Use HORIZONTAL

SCALE to modify this parameter.

6. Waveform Memory

Provide the schematic diagram of the memory position of the waveform
currently on the screen.

7. Trigger Position

Display the trigger positions of the waveform in the waveform memory and
on the screen.

8. Trigger Position

Use HORIZONTAL POSITION to modify this parameter. Press down
the knob to automatically set the parameter to zero.

9. Trigger Type

Display the currently selected trigger type and trigger condition setting.
Different labels are displayed when different trigger types are selected.
For example, represents triggering on the rising edge in “Edge” trigger.

waveform on the
screen