Slope trigger, Slope trigger -11 – RIGOL DS6000 Series User Manual
Page 103

RIGOL
DS6000 User’s Guide
5-11
Slope Trigger
Trigger on the positive or negative slope with specified time.
Trigger Type:
Press Type to select “Slope”. At this point, the trigger setting information as shown
in the figure below is displayed at the upper right corner of the screen.
Source Selection:
Press Source to select CH1-CH4 as the Trigger Source. The current trigger source
is displayed at the upper right corner of the screen.
Note: select channel with signal input as trigger source to obtain stable trigger.
Slope Condition:
Press When to select the desired slope condition.
: trigger when the positive slope time of the input signal is greater than
the specified Time.
: trigger when the positive slope time of the input signal is lower than the
specified Time.
: trigger when the positive slope time of the input signal is greater than
the specified Lower Limit of Time and lower than the specified Upper Limit of
Time.
: trigger when the negative slope time of the input signal is greater than
the specified Time.
: trigger when the negative slope time of the input signal is lower than
the specified Time.
: trigger when the negative slope time of the input signal is greater than
the specified Lower Limit of Time and lower than the specified Upper Limit of
Time.