beautypg.com

Slope trigger, Slope trigger -11 – RIGOL DS6000 Series User Manual

Page 103

background image

5 To Trigger the Oscilloscope

RIGOL

DS6000 User’s Guide

5-11

Slope Trigger


Trigger on the positive or negative slope with specified time.

Trigger Type:
Press Type to select “Slope”. At this point, the trigger setting information as shown
in the figure below is displayed at the upper right corner of the screen.


Source Selection:

Press Source to select CH1-CH4 as the Trigger Source. The current trigger source

is displayed at the upper right corner of the screen.
Note: select channel with signal input as trigger source to obtain stable trigger.

Slope Condition:
Press When to select the desired slope condition.

: trigger when the positive slope time of the input signal is greater than

the specified Time.

: trigger when the positive slope time of the input signal is lower than the

specified Time.

: trigger when the positive slope time of the input signal is greater than

the specified Lower Limit of Time and lower than the specified Upper Limit of

Time.

: trigger when the negative slope time of the input signal is greater than

the specified Time.

: trigger when the negative slope time of the input signal is lower than

the specified Time.

: trigger when the negative slope time of the input signal is greater than

the specified Lower Limit of Time and lower than the specified Upper Limit of

Time.