5 To Trigger the Oscilloscope

DS6000 User’s Guide

5-30

USB Trigger


Trigger on the SOP, EOP, RC, Suspended and Exit Suspended of the data packet on
the differential USB data cable (D+ and D-). This trigger supports USB Low Speed
and Full Speed. The figure below shows the USB data transmission protocol.


Trigger Type:
Press Type to select “USB”. At this point, the trigger setting information as shown in
the figure below is displayed at the upper right corner of the screen.


Source Selection:
Press D+ and D- to specify data sources for D+ and D- data cables respectively.

CH1-CH4 can be selected as the data source. The current trigger source is displayed

at the upper right corner of the screen.

Signal Speed:
Press Speed to select “Low Speed” (1.5 Mb/s) or “Full Speed” (12 Mb/s).

Trigger Condition:
Press When to select the desired trigger condition.
SOP: trigger at the sync bit

at the beginning of the data packet (SOP).

EOP: trigger at the end of the SEO portion of the data packet (EOP).
RC: trigger when SEO is greater than 10 ms.
Suspended: trigger when the idle time of the bus is greater than 3 ms.
ExitSuspended: trigger when the bus exits from idle state for more than 10

ms.