5 To Trigger the Oscilloscope

RIGOL

DS6000 User’s Guide

5-15

 PAL: the frame frequency is 25 frames per second. The TV sweep line is 625

with the odd field goes first and the even field follows behind.

 SECAM: the frame frequency is 25 frames per second. The sweep line is 625

with interlacing sweep.

 HDTV: HDTV consists of 480P, 576P, 720P, 1080P and 1080I display formats.

The specified video standards are as follows:

480P

the frame frequency is 60 frames per second; the TV sweep

line is 525; line-by-line sweep; the line frequency is 31.5

kHz.

576P

the frame frequency is 60 frames per second; the TV sweep

line is 625; line-by-line sweep.

720P

the frame frequency is 60 frames per second; the TV sweep

line is 750; line-by-line sweep; the line frequency is 45 kHz.

1080P

the frame frequency is 60 frames per second; the TV sweep

line is 1125; line-by-line sweep.

1080I

the field frequency is 50 to 60 fields per second; the frame

frequency is 25 to 30 frames per second; the TV sweep line

is 1125; interlacing sweep; the line frequency is 33.75 kHz.

Trigger Mode:

Press Sweep to select the Trigger Mode (page 5-3) under this trigger type as auto,

normal or single. The corresponding status light of the current trigger mode turns on.

Trigger Setting:

Press Setting to set the trigger parameters (trigger holdoff) under this trigger type.

Trigger Level:
Use TRIGGER LEVEL to modify the level. For details, please refer to the
description of “Trigger Level” on page 5-8.