Flexray decoding (option), Flexray decoding (option) -19 – RIGOL DS6000 Series User Manual
Page 177
RIGOL
DS6000 User’s Guide
7-19
FlexRay Decoding (Option)
Press MATH BUS1 Decode and select “FlexRay” to open the FlexRay
decoding function menu.
1. Source
Press Source to select any channel (CH1 to CH4) as the signal source channel.
2. Signal Path
Press Signal Path to select the signal path (A or B) that matches the FlexRay
bus signal.
3. Signal Type
Press Signal Type to select the type of signal that matches the FlexRay bus.
The signal types available include BP, BM and TX/RX.
4. Baud
Press Baud to set the signal rate (2.5 Mb/s, 5Mb/s or 10 Mb/s) that matches the
FlexRay bus signal.
5. Sample Point
The sample point is the point within the bit time.The oscilloscope samples the bit
level at this point. The sample point position is expressed by the percentage of
the “time from the start of bit to the sample bit” takes up in “bit time”.
Press Sample Point and use
to adjust this parameter with a step of 1%
and the range is from 5% to 95%.
6. Threshold
Refer to the introduction in Parallel Decoding.
1 bit
60%
70%
80%