RIGOL DS6000 Series User Manual
Page 236
RIGOL
DS6000 User’s Guide
13-4
nnn is from 0 to 223 (except 127) and the ranges of the other three nnn are
from 0 to 255. You are recommended to ask your network administrator for an
IP address available.
Press IP Address and use
to input the desired IP address. This setting will
be saved in the non-volatile memory and if Power On is set to “Last”, DHCP
and Auto IP will be “Off” and the oscilloscope will load the preset IP address
automatically at the next power-on.
2. Set the Subnet Mask.
The format of the subnet mask is nnn.nnn.nnn.nnn, where, the range of the nnn
is from 0 to 255. You are recommended to ask your network administrator for a
subnet mask available.
Press Mask and use
to input the desired subnet mask. This setting will be
saved in the non-volatile memory and if Power On is set to “Last”, DHCP and
Auto IP will be “Off” and the oscilloscope will load the preset subnet mask
automatically at the next power-on.
Set the Gate
You can set this paramter In Auto IP and Static IP mode.
The format of the gate is nnn.nnn.nnn.nnn, where, the range of the first nnn is from
0 to 223 (except 127) and the ranges of the other three nnn are from 0 to 255. You
are recommended to ask your network administrator for a gate address available.
Press Gate and use
to input the desired gate address. This setting will be saved
in the non-volatile memory and if Power On is set to “Last”, DHCP and Auto IP will
be “Off” and the oscilloscope will load the preset gate address automatically at the
next power-on.
Set the Domain Name Server
You can set this paramter In Auto IP and Static IP mode.
The address format of the domain name server is nnn.nnn.nnn.nnn, where, the