background image

24

2 Manual Operation and Setup

2.4 D

a

tu

m

Set

ting

(With

out a 3

-D T

ouc

h

Pr

ob

e)

2.4 Datum Setting (Without a 3-D

Touch Probe)

Note

You fix a datum by setting the TNC position display to the coordinates
of a known position on the workpiece.

Preparation

U

U

U

U

Clamp and align the workpiece.

U

U

U

U

Insert the zero tool with known radius into the spindle.

U

U

U

U

Ensure that the TNC is showing actual position values.

For datum setting with a 3-D touch probe, refer to the