beautypg.com

11 position display types, Function, Select position display – HEIDENHAIN TNC 410 ISO Programming User Manual

Page 436

background image

410

12 MOD Functions

12.1

1

P

o

sition

Disp

la

y T

y

pe

s

12.11 Position Display Types

Function

In the Manual Operation mode and in the Program Run modes of
operation, you can select the type of coordinates to be displayed.

The figure at right shows the different tool positions:

n

Starting position

n

Target position of the tool

n

Workpiece datum

n

Machine datum

The TNC position displays can show the following coordinates:

With the MOD function Position display 1, you can select the position
display in the status display.

With Position display 2, you can select the position display in the
additional status display.

Function

Display

Nominal position: the value presently
commanded by the TNC

NOML.

Actual position; current tool position

ACTL.

Reference position; the actual position relative to
the machine datum

REF

Distance remaining to the programmed position;
difference between actual and target positions

DIST.

Servo lag: difference between nominal and actual
positions (following error)

LAG

Deflection of the measuring touch probe

DEFL.

Traverses that were carried out with handwheel
superpositioning (M118)
(only position display 2, not TNC 410)

M118