beautypg.com

1 gener a l user p a ra met e rs – HEIDENHAIN TNC 410 ISO Programming User Manual

Page 453

background image

HEIDENHAIN TNC 410, TNC 426, TNC 430

427

13.1 Gener

a

l User P

a

ra

met

e

rs

Coordinates of the TT 120 stylus center
relative to the machine datum

MP6580.0 (traverse range 1)
X axis

MP6580.1 (traverse range 1)
Y axis

MP6580.2 (traverse range 1)
Z axis

MP6581.0 (traverse range 2), (not TNC 410)
X axis

MP6581.1 (traverse range 2), (not TNC 410)
Y axis

MP6581.2 (traverse range 2), (not TNC 410)
Z axis

MP6582.0 (traverse range 3), (not TNC 410)
X axis

MP6582.1 (traverse range 3), (not TNC 410)
Y axis

MP6582.2 (traverse range 3), (not TNC 410)
Z axis

TNC displays, TNC editor

Programming station

MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2

Acknowledgment of
POWER INTERRUPTED
after switch-on

MP7212
Acknowledge with key: 0
Acknowledge automatically: 1

ISO programming: Set
the block number
increment

MP7220
0
to 150

Disabling the selection
of file types

MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A): +32 (not TNC 410)
Disable selection of point tables (soft key SHOW .PNT): +64 (not TNC 410)

3-D touch probes and digitizing