Coordinates of the TT 120 stylus center
relative to the machine datum
MP6580.0 (traverse range 1)
X axis
MP6580.1 (traverse range 1)
Y axis
MP6580.2 (traverse range 1)
Z axis
MP6581.0 (traverse range 2), (not TNC 410)
X axis
MP6581.1 (traverse range 2), (not TNC 410)
Y axis
MP6581.2 (traverse range 2), (not TNC 410)
Z axis
MP6582.0 (traverse range 3), (not TNC 410)
X axis
MP6582.1 (traverse range 3), (not TNC 410)
Y axis
MP6582.2 (traverse range 3), (not TNC 410)
Z axis
TNC displays, TNC editor
Programming station
MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2
Acknowledgment of
POWER INTERRUPTED
after switch-on
MP7212
Acknowledge with key: 0
Acknowledge automatically: 1
ISO programming: Set
the block number
increment
MP7220
0 to 150
Disabling the selection
of file types
MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A): +32 (not TNC 410)
Disable selection of point tables (soft key SHOW .PNT): +64 (not TNC 410)