HEIDENHAIN TNC 410 ISO Programming User Manual
Page 407

HEIDENHAIN TNC 410, TNC 426, TNC 430
381
11
.4
P
ro
g
ra
m
R
u
n
U
U
U
U
To go to the first block of the current program to
start a block scan, enter GOTO "0".
U
U
U
U
To select mid-program startup, press the
RESTORE POS AT N soft key.
U
U
U
U
Start-up at N:
Enter the block
number N at which the block scan
should end.
U
U
U
U
Program:
Enter the name of the
program containing block N.
U
U
U
U
Repetitions:
If block N is located in
a program section repeat, enter the
number of repetitions to be
calculated in the block scan.
U
U
U
U
PLC ON/OFF (not TNC 426, TNC
430): To account for tool calls and
miscellaneous functions M: Set the
PLC to ON (use the ENT key to
switch between ON and OFF). If
PLC is set to OFF, the TNC
considers only the geometry. The
tool in the spindle must equal the
tool called by the program.
U
U
U
U
To start the block scan,
TNC 426, TNC 430: Press the
machine START key.
TNC 410: Press the START soft
key.
U
U
U
U
To return to the contour, see