beautypg.com

HEIDENHAIN TNC 410 ISO Programming User Manual

Page 222

background image

196

8 Programming: Cycles

8.3 Cy

cles f

o

r Dr

illing

, T

a

p

p

ing

and

Th

read Millin

g

U

U

U

U

Set-up clearance

Q200 (incremental value): Distance

between tool tip and workpiece surface.

U

U

U

U

Depth

Q201 (incremental value): Distance between

workpiece surface and bottom of hole (tip of drill
taper).

U

U

U

U

Feed rate for plunging

Q206: Traversing speed of

the tool during drilling in mm/min.

U

U

U

U

Plunging depth

Q202 (incremental value): Infeed per

cut. The depth does not have to be a multiple of the
plunging depth. The TNC will go to depth in one
movement if:

n

the plunging depth is equal to the depth

n

the plunging depth is greater than the depth

U

U

U

U

Workpiece surface coordinate

Q203 (absolute

value): Coordinate of the workpiece surface.

U

U

U

U

2nd set-up clearance

Q204 (incremental value):

Coordinate in the tool axis at which no collision
between tool and workpiece (clamping devices) can
occur.

U

U

U

U

Decrement

Q212 (incremental value): Value by which

the TNC decreases the plunging depth Q202.

U

U

U

U

Minimum plunging depth

Q205 (incremental value): If

you have entered a decrement, the TNC limits the
plunging depth to the value entered with Q205.

U

U

U

U

Upper advanced stop distance

Q258 (incremental

value): Set-up clearance for rapid traverse positioning
when the TNC moves the tool again to the current
plunging depth after retraction from the hole; value
for the first plunging depth

U

U

U

U

Lower advanced stop distance

Q259 (incremental

value): Set-up clearance for rapid traverse positioning
when the TNC moves the tool again to the current
plunging depth after retraction from the hole; value
for the last plunging depth.

U

U

U

U

Infeed depth for chip breaking

Q257 (incremental

value): Depth at which the TNC carries out chip
breaking. There is no chip breaking if 0 is entered.

U

U

U

U

Retraction rate for chip breaking

Q256

(incremental value): Value by which the TNC retracts
the tool during chip breaking.

U

U

U

U

Dwell time at depth

Q211: Time in seconds that the

tool remains at the hole bottom.

Example: NC block

N12 G205 Q200=2 Q201=-80 Q206=150
Q202=15 Q203=+100 Q204=50 Q212=0.5

Q205=3 Q258=0.5 Q259=1 Q257=5
Q256=0.2 Q211=0.25 *

If you enter Q258 not equal to Q259, the TNC will change
the advance stop distances between the first and last
plunging depths at the same rate.