beautypg.com

3 test run, Function, 3 t e st ru n 11.3 test run – HEIDENHAIN TNC 410 ISO Programming User Manual

Page 398

background image

372

11 Test Run and Program Run

1

1

.3 T

e

st

Ru

n

11.3 Test Run

Function

In the Test Run mode of operation you can simulate programs and
program sections to prevent errors from occurring during program run.
The TNC checks the programs for the following:

n

Geometrical incompatibilities

n

Missing data

n

Impossible jumps

n

Violation of the machine's working space

The following functions are also available:

n

Blockwise test run

n

Interrupt test at any block

n

Optional block skip

n

Functions for graphic simulation

n

Measuring the machining time

n

Additional status display

Running a program test

If the central tool file is active, a tool table must be active (status S) to
run a program test. Select a tool table via the file manager (PGM MGT)
in the Test Run mode of operation.

With the MOD function BLANK IN WORK SPACE, you can activate
work space monitoring for the test run, see “Showing the Workpiece
in the Working Space (not TNC 410),” page 408.

U

U

U

U

Select the Test Run mode of operation.

U

U

U

U

Call the file manager with the PGM MGT key and

select the file you wish to test, or

U

U

U

U

Go to the program beginning: Select line “0” with the

GOTO key and confirm your entry with the ENT key.

The TNC then displays the following soft keys:

Function

Soft key

Test the entire program

Test each program block individually

Show the blank form and test the entire program

Interrupt the test run