Procedure

During a program run or test run, you can check or change Q
parameters if necessary.

U

U

U

U

If you are in a program run, interrupt it (for example, by pressing the
machine STOPP button and the INTERNAL STOP soft key). If you
are in a test run, interrupt it.

U

U

U

U

To call the Q parameter functions, press the Q key.

U

U

U

U

TNC 426, TNC 430:

Enter the Q parameter number and press the ENT
key. The TNC displays the current value of the Q
parameter in the dialog line.

U

U

U

U

TNC 410:

Using the arrow keys you can select a Q-parameter
on the current screen page. With the PAGE soft keys,
you can go to the next or the previous
screen page.

U

U

U

U

If you wish to change the value, enter a new value,

confirm it with the ENT key and conclude your entry
with the END key.

U

U

U

U

To leave the value unchanged, terminate the dialog

with the END key.