System configuration, Introduction, Configuring jupiter to support tmv – Grass Valley Trinix Multiviewer Installation User Manual
Page 80: Section 5 — system configuration

TRINIX - TMV Installation and Service Manual
80
Section
5
System Configuration
Introduction
This section provides Control system configuration information so that the 
Trinix Multiviewer (TMV) board may access the control system. The TMV 
will need to have access to level source and destination information for the 
following Control systems:
•
Jupiter AccuSwitch (Version 7.9.1 and newer.)
•
Encore (Version 1.8.2 and newer.
The TMV Facility LAN IP addresses are entered in the Jupiter and Encore 
Control System configuration. Refer to the latest control system’s manual 
and release notes for information that is specific to the control system.
Configuring Jupiter to Support TMV
Jupiter must be configured to support TMV. This will allow the TMV to 
communicate with an AccuSwitch controller. Before starting this process, 
make sure that you have the latest version of the Jupiter AccuSwitch soft-
ware. 
You will need to access the following tables in the Jupiter Configuration 
Editor application (the Configurator):
•
Network Description
•
MPK Table
•
Control Panel Input set
•
Control Panel Output Set
•
Control Panel Level set
You will need to add a minimum of two rows to the Network description 
table and MPK Table, one row for the TMV board and one for the TMV PC. 