Reference connections – Grass Valley Trinix Multiviewer Installation User Manual
Page 48

TRINIX — TMV Installation and Service Manual
48
TMV Rear Panel Connections
2.
Connect the local network’s cable to the FAC connection. The
Following applications and messages use the FAC LAN:
•
Native Protocol (Router Control Systems)
•
NetConfig
•
TMV Configuration Editor (To request the Router Control System’s
tables.)
•
Optional Tally system
Figure 5. CNTL and FAC Connections
Both LAN cables must be connected before starting the TMV system. This
step is required for the TMV system to gather the information needed.
Reference Connections
Video reference information is imported using the REF connections. Refer-
ence is a passive loop through the rear panel.
, for Supported Reference Types
Vertical Interval Time Code (VITC) is imported through the REF connec-
tion.
Importing Reference Information
Follow these steps to import Reference information into the TMV board:
1.
Connect the Reference source connector to one of the REF connections.
2.
Connect the Reference sink connector (or a 75-ohm termination BNC)
to the other REF connection.
071873500_TMV-LAN_connections
Connect the Facility
Network to the FAC
Connections
Connect the TMV
Network to the CNTL
Connections