beautypg.com

The smpte 425m-b standard is supported, Environmental conditions, Power requirements – Grass Valley Trinix Multiviewer Installation User Manual

Page 217: Electrical parameters

background image

217

TRINIX — TMV Installation and Service Manual

Appendix A — TMV Specifications

Note

Grass Valley does not recommend using the 720p/50, 720p/59.94, 1080p/50,
and 1080p/59.94 tri-level sync reference types. These types have two-frame
alignment ambiguity with video streams that have half the reference frame
rate. The TMV board does support these types and user discretion is advised.

The SMPTE 425M-B Standard is Supported

The transmission of two non-3G/b signals (For example, HD-SDI) over a
3Gig-SDI link is supported in the TMV system.

For reference, SMPTE 425M is a standard that specifies the mapping of dif-
ferent video signals to the 3G physical interface as well as the supported
video formats.

The Level A variant refers to the carrying of a single high bit rate video
signal over a 3Gig-SDI link.

The Level B variant refers to the transmission of two lower bit rate
signals (For example, HD-SDI) over a 3Gig-SDI link.

Environmental Conditions

Temperature: 0 - 35 degrees Celsius (32 - 95 degrees Fahrenheit).

Humidity: 10-90%, non-condensing.

Power Requirements

100 W (per module)

Electrical Parameters

TMV Electrical Length for a Monitor Output with N cascade stages

(0 <= N < 16): = 1 to 2 field periods of the interlaced reference input, plus
N*400/148.5MHz, plus one output video line period (for interlaced
outputs only);

TMV Reference Input Frequency Tolerance

+/-50ppm.

TMV Video input Frequency Tolerance

+/-50ppm.