Tmv board location – Grass Valley Trinix Multiviewer Installation User Manual
Page 35

35
TRINIX — TMV Installation and Service Manual
Section 2 — Hardware Installation
Trinix Asymmetrical Frames
The Trinix asymmetrical frames will support the following number of
Trinix boards:
•
128 x 256 supports up to 8 TMV boards
•
256 x 512 supports up to 8 TMV boards
•
512 x 1024 supports up to 16 TMV boards
Trinix Symmetrical Frames
The TMV output boards may also be used in existing symmetrical Trinix
NXT frames but in a limited manner. Due to the increased power and
cooling requirements, an extra space next to each TMV board is required
for ventilation.
The supported number of TMV boards in an existing symmetrical Trinix
NXT frame is:
•
128x128 supports up to 2 TMV boards
•
256x256 supports up to 4 TMV boards
•
512x512 supports up to 4 TMV boards
TMV Board Location
The TMV board may be placed in any Output slot for the 128x256 and the
512x1024 Trinix Routing switchers. Grass Valley recommends that you
ONLY install the TMV board in the following output ranges of the identi-
fied routing switchers. See
for more information
The boards may be installed in any of the allowed slots identified but
MUST cascade in ascending order. They do not have to be installed begin-
ning with the first available output slot and slots may be skipped.
Table 3. Recommended TMV Location
Routing Switcher
Size
Output Range
256x512
Jupiter: 128-159, 160-191, 192-223, 224-255, 256-287, 288-319, 320-351, and 352-383,
Encore: 129-160, 161-192, 193-224, 225-256, 257-288, 289-320, 321-352, and 353-384
128x128
*
Jupiter: 0-31 and 64-95 only.
Encore: 1-32 and 65-96 only.
256x256
*
Jupiter: 0-31, 64-95, 128-159, and 192-223 only.
Encore: 1-32, 65-96, 129-160, and 193-224 only.
512x512
*
Jupiter: 0-31, 64-95, 128-159, and 192-223 only.
Encore: 1-32, 65-96, 129-160, and 193-224 only.