3 requirements, 1 environmental requirements, Table 2-1 – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 41: Environmental requirements, Hardware preparation and installation

Hardware Preparation and Installation
MVME2502 Installation and Use (6806800R96E)
41
2.3
Requirements
Make sure that the board meets the following requirements when operated in your particular
system configuration.
2.3.1
Environmental Requirements
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Table 2-1 Environmental Requirements
Characteristics
Commercial Versions
Extended Temperature Versions
Applicable Variants
MVME2502-02120201E/S
MVME2502-02120202E/S
MVME2502-02100202E
MVME2502-02100202S
Cooling Method
Forced Air
Forced Air
Operating
Temperature
0°C to +55°C
-40°C to +71°C
Storage
-40°C to +85°C
-50°C to +100°C
Vibration Sine
(10min/axis)
2 G, 5 to 500 Hz
5 G, 15 to 2000 Hz
Vibration Random
(1hr/axis)
0.002g2/Hz, 15 to 2000 Hz
0.04g2/Hz, 15 to 2000 Hz (8
GRMS)
2
Shock
20g/11 mS
30g/11 mS
Humidity
to 95% RH (non-condensing)
to 100% RH (non-condensing)
1. ft3/min
2. Flat 15-1000Hz, -6db/octave 1000Hz - 2000Hz [MIL-STD 810F Figure 514.5C-17]
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)