14 reset/control cpld, 15 power management, 1 on-board voltage supply requirement – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 102: 14 reset/control cpld 4.15 power management, Table 4-5, Voltage supply requirement, Functional description

Functional Description
MVME2502 Installation and Use (6806800R96E)
102
4.14 Reset/Control CPLD
The CPLD provides the following functions:
Power control and fault detection
Reset sequence and reset management
Status and control registers
Miscellaneous control logic
Watchdog timer
32-bit Tick Timer
Clock generator
Switch decoder and LED controller
4.15 Power Management
The MVME2502 backplane is utilized to derive +3.3V, +2.5V, +1.8V, +1.5V, +1.2V, +1.05V
voltage rail. Each voltage rail is controlled by the CPLD through an enable pin of the regulator,
while the output is monitored through power good signal. If a voltage rail fails, the CPLD will
disable all of the regulators. To restart the system, the chassis power switch must be power-
cycled.
4.15.1 On-board Voltage Supply Requirement
The on-board power supply is considered to be out of regulation if the output voltage level is
below the minimum required power or goes beyond the maximum.
Table 4-5 Voltage Supply Requirement
Voltage Rail
Voltage Rail Requirement
Minimum
Maximum
+3.3 V
3.15 V
3.45 V
+2.5 V
2.375 V
2.625 V
+1.8 V
1.7 V
1.9 V
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)