Table 5-19 – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 126

Memory Maps and Registers
MVME2502 Installation and Use (6806800R96E)
126
5.5.16 PLD Shutdown and Reset Control and Reset Reason Register
The MVME2502 provides an 8-bit register to execute the shutdown and reset commands. The
board's reset reason is also included in this register.
Field Description
CPU_RTC_SEL
CPU RTC Input Select
0-1.824MHz (default)
1-SQW/INTB from DS1337 RTC
SW2-3
SW2-3 state (User defined)
0-SW2-3 closed
1-SW2-3 open (default)
NMI
Abort switch interrupt if pressed less than three seconds.
1 - Interrupt enabled
0 - No Interrupt
TICK0_INT
Tick Timer 0 interrupt
1 - Interrupt enabled
0 - No Interrupt
TICK1_INT
Tick Timer 1 interrupt
1 - Interrupt enabled
0 - No Interrupt
TICK2_INT
Tick Timer 2 interrupt
1 - Interrupt enabled
0 - No Interrupt
Table 5-19 PLD Shutdown and Reset Control and Reset Reason Register
REG
PLD Shutdown and Reset Reason- 0xFFDF00FF
Bit
7
6
5
4
3
2
1
0
Field
RSVD
Shutdown
Soft_RST
Clear_Cause
CPU_RESET
WD_TIME
OUT
LRSTO
Sft_RST
OPER
R
W
W
W
R
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)