9 pld pci/pmc/xmc (slot2) monitor register, Table 5-12, Pld pci/pmc/xmc (slot2) monitor register – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 119

Memory Maps and Registers
MVME2502 Installation and Use (6806800R96E)
119
5.5.9
PLD PCI/PMC/XMC (Slot2) Monitor Register
The MVME2502 PLD provides an 8-bit register which indicates the status of the
SATA/PMC/XMC interface signals.
PMC1_EREADY
Indicates PCI device is ready for enumeration.
1 - PMC ready for enumeration
0 - PMC is not ready for enumeration
PMC1P_N
PMC Presence Indicator
1 - PMC is not present
0 - PMC is present
XMCP1_N
XMC Presence Indicator
1 - XMC is not present
0 - XMC is present
PCI1_PCIXCAP
PCI Capability Indicator
1 - PCI-X capable
0 - PCI capable
Table 5-12 PLD PCI/PMC/XMC (Slot2) Monitor Register
REG
PLD PCI_PMC_XMC_MNTR - 0xFFDF001F
Bit
7
6
5
4
3
2
1
0
Field
SD1_M
UX_SEL
1
SD1_M
UX_SEL
0
SW2-4
PMC2_E
READY
SATA0_
DETECT
_N
PMC2P_
N
XMCP2_
N
PMC2_P
CIXCAP
OPER
R
RESET
X
X
X
X
X
X
X
X
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)