3 interrupt controller, Table 7-2, Mvme2502 interrupt list – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 149: Programming model
Programming Model
MVME2502 Installation and Use (6806800R96E)
149
7.3
Interrupt Controller
The MVME2502 uses the MPC8548E integrated programmable interrupt controller (PIC) to
manage locally generated interrupts. Currently defined external interrupting devices, interrupt
assignments, along with corresponding edge/levels, and polarities are shown in the following
table.
Table 7-2 MVME2502 Interrupt List
Interrupt Line
Interrupt Usage
(Schematic)
Interface to CPU
Description
IRQ0
None
Reserved for VME interrupt
IRQ1
QUART_IRQ1
LBC
RTB Quart Interrupt
IRQ2
QUART_IRQ2
LBC
RTB Quart Interrupt
IRQ3
QUART_IRQ3
LBC
RTB Quart Interrupt
IRQ4
Temperature
Interrupt
I2C
Two on-board Thermal Sensors:
one is for CPU temp and the
other is for board temp
IRQ5
Ethernet 1
Management I2C
Ethernet interrupt is handled by
PHY/ Connected for flexibility
IRQ6
Ethernet 3
Management I2C
Ethernet interrupt is handled by
PHY/ Connected for flexibility
IRQ7/ GPIO0
Ethernet 2
Management I2C
Ethernet interrupt is handled by
PHY/ Connected for flexibility
IRQ8/ GPIO1
RTC (Real Time
Clock)
12C
DS1337 INT_A
IRQ9/ GPIO2
CPLD Interrupt
LBC
NMI and 3 Tick Timer Interrupts
IRQ10// GPIO3
CPLD Interrupt
LBC
Not used
IRQ11// GPIO4
QUART_IRQ0
LBC
RTB Quart Interrupt
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)