Programming model – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 147

Programming Model
MVME2502 Installation and Use (6806800R96E)
147
18
ETSEC2 SGMII
Mode
LGPL1
1
eTSEC2 Ethernet
interface operates in
standard parallel
interface mode and uses
the TSEC_2’pins
(default).
19
ETSEC3 SGMMI
Mode
TSEC_1588_ALARM
_OUT2
1
eTSEC3 Ethernet
interface operates in
standard parallel
interface mode and uses
the TSEC_3’pins
(default).
20
ETSEC1 and
ETSEC2 Width
EC_MDC
0
eTSEC1 and eTSEC2
Ethernet interfaces
operate in reduced pin
mode (either RTBI, RGMI,
RMII or 8-bit FIFO mode).
21
ETSEC1
Protocol
TSEC1_TXD0,
TSEC1_TXD7
10
The eTSEC2 controller
operates using the GMII
protocol (or RGMII, if
configured in reduced
mode) if its not
configured to operate in
SGMII mode.
22
ETSEC2
Protocol
TSEC2_TXD0,
TSEC2_TXD7
10
The eTSEC2 controller
operates using the GMII
protocol (or RGMII, if
configured in reduced
mode) if its not
configured to operate in
SGMII mode.
23
ETSEC3
Protocol
UART_RTS0,
UART_RTS1
10
The eTSEC3 controller
operates using the RGMII
protocol if not configured
to operate in SGMII
mode.
Table 7-1 POR Configuration Settings (continued)
CONFIG
CONFIG PINS
CONFIG
SELECTION
REMARKS
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)