21 pld watchdog timer count value register, 6 external timer registers, 1 prescaler register – Artesyn MVME2502 Installation and Use (April 2015) User Manual
Page 130: Table 5-24, Pld watchdog timer count register

Memory Maps and Registers
MVME2502 Installation and Use (6806800R96E)
130
5.5.21 PLD Watchdog Timer Count Value Register
The MVME2502 provides a watchdog timer count value register.
5.6
External Timer Registers
The MVME2502 provides a set of tick timer registers to access the three external timers
implemented in the timers/registers PLD. These registers are 32-bit and are word writable. The
following sections describe the timer prescaler and control register:
5.6.1
Prescaler Register
The prescaler adjust value is determined by this formula:
Field Description
Count
Count. These bits define the watchdog timer count value. When the
watchdog counter is enabled, it will count up from zero (reset value) with a 1
ms resolution until it reaches the COUNT value set by this register. Watchdog
will generate a soft reset signal if it bites.
Setting this register to 0xEA60 or 60,000 counts will provide a watchdog
timeout of 60 seconds.
Table 5-24 PLD Watchdog Timer Count Register
REG
PLD Watchdog Timer Count Value- 0xffc80608
Bit
15:0
Field
Count Value
OPER
R
RESET
0x0000
Field Description
Count
Value
Count value. These bits indicate the current value of the watch dog counter.
- MVME2502 Installation and Use (August 2014) MVME2500 Installation and Use Manual (February 2014) MVME2500 ECC Installation and Use (August 2014) MVME2500 Installation and Use (April 2015) MVME2500 Installation and Use Manual (March 2015) MVME2502 Installation and Use (April 2014) MVME2502 Installation and Use (December 2014)