Step-level timing – PRG Vx76 User Manual 3.6 User Manual
Page 201
VX76 SOFTWARE USER MANUAL
185
Step-Level Timing
Timing can be programmed on a sequence step-level to control the step, attack, sustain, and decay for each step in
the sequence.
Note: When cues are included in sequences, the cue times will override step attack times, unless timing is disabled
by the Function Filter. (Refer to
+
Step - The time between activation of a step and the next sequential step. This can also be controlled on a
universal level in the effects timing attributes (refer to
+
Attack - Transition time between current luminaire state and state dictated by the step action.
+
Sustain - How long the channels will execute the action.
+
Decay - Transition time out of a step into a background state. This is used only in a situation where the effect is in
Break mode and the attack and sustain times are longer than the total step time.
Step 1
Step 2
Decay
Background State
Step Time
Step Time
Attack
Sustain
Attack
Sustain