PRG Vx76 User Manual 3.6 User Manual
Page 200
184
VX76 SOFTWARE USER MANUAL
When
Time
is selected, this number will be the length of time, in seconds, that the effect will run before initiating
its Fade Out.
Note: If "N/A" is selected as the Duration attribute, then this value will not be used.
+
Zero State Fade - While a channel is fading to a Zero State and another cue is executed with an Out Time
before
the Zero State finishes its fade, the Zero State channels will now continue to use the Zero State time. The
following diagrams represents the new action:
+
Step - The time between activation of a sequence step and the next sequential step. On an effects level, Step
Time can be used in two ways: either to set all sequence steps to the same timing value or to scale the timing
values of sequence steps (when sequence steps have different timing values already stored). Step times can also
be set individually (refer to
on page 186) or scaled by turning the encoder. The step
time shown is that of the last step.
100
Zero State
Another Cue executed
This cue is ignored
10 Second Fade
and fade continues
to Zero State
- go to Out State in 0 time
Cue executed
- fade to Zero State in 10 seconds
x