TOSHIBA

i6,F,8,A0,8,6,9,

8.2.6 Password Setting

The password function is provided to protest the settings and adjustment of the functions affecting
the flow rate measurement. See 7.4 ‘^Conflguration Items Selection Table” for limited functions.

Proceed as follows to check or change the password.

• To check the password:

Key operation

Display example

Description

A:

MEAS MODE

EX CURRENT
METER SIZE
EX FREQ

FLOW DIRECTN

^PASSWORD

ADDRSET

[SEL] [ENT]

Select "PASSWORD" in the configuration item

selection screen.

A5:

PASSWORD

123

The currently set password is displayed.

[ENT]

[EXT] [ENT]

[EXT]

A:

MEAS MODE

^EX CURRENT

METER SIZE
EX FREQ
FLOW DIRECTN
PASSWORD

ADDRSET

_[SEy_______

W

________

You return to the configuration item selection

screen.

* However, if a wrong password is entered when the mode is changed from the measuring mode to

the setting mode, *** appears.

Key operation

Display example

Description

A5:

PASSWORD

The currently set password is displayed as ***.

[ENT]

IEXT1 [ENTI

63

-