8.2.6 Password Setting
The password function is provided to protest the settings and adjustment of the functions affecting
the flow rate measurement. See 7.4 ‘^Conflguration Items Selection Table” for limited functions.
Proceed as follows to check or change the password.
• To check the password:
Key operation
Display example
Description
A:
MEAS MODE
EX CURRENT
METER SIZE
EX FREQ
FLOW DIRECTN
^PASSWORD
ADDRSET
[SEL] [ENT]
Select "PASSWORD" in the configuration item
selection screen.
A5:
PASSWORD
123
The currently set password is displayed.
[ENT]
[EXT] [ENT]
[EXT]
A:
MEAS MODE
^EX CURRENT
METER SIZE
EX FREQ
FLOW DIRECTN
PASSWORD
ADDRSET
_[SEy_______
W
________
You return to the configuration item selection
screen.
* However, if a wrong password is entered when the mode is changed from the measuring mode to
the setting mode, *** appears.
Key operation
Display example
Description
A5:
PASSWORD
The currently set password is displayed as ***.
[ENT]
IEXT1 [ENTI