Output, Communication signal, Cable connection port: 1/2-14npt thread – Toshiba LF600F User Manual
Page 152: Toshiba
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
6,F,8,A0i8,6,9,
Output
Current output:
Digital output 1:
Digital output 2:
4 to 20mAdc (load resistance 750 Q or less)
Output type:
Transistor open collector
Capacity:
30Vdc, Max 200mA
Number of output points: 1
(Option)
Output type:
Semiconductor contact signal output (no polarity)
Capacity:
150Vdc, Max. 150mA
150Vac (peak value), Max. 100mA
Number of output points : I
Digital output function: Select one of the following:
•
Totalization pulse output:
Pulse rate
Max. lOkHz(lOOOOpps) ••• DOl
Max. 100Hz( lOOpps) ••• D02 (option)
Pulse width Can be set within a range of 0.3 to 500ms.
However, must be 1/2 or less of the full-scale cycle.
If the full scale lOOOpps is exceeded,
automatically set to 40% of the full-scale cycle.
• Multi-range switching output: In the case of fourfold range or forward/reverse
double range, you need to add digital output optionally.
High and low alarm output
High-high and low-low alarm output
Empty alarm output
Preset counter output
Converter malfunction alarm output
Multiple range high and low limit alarm output (option)
Output display: Full-dot matrix 128 x 128-dot LCD (with back light)
Communication signal
Method (protocol):
Load resistance:
Load capacity:
HART or PROFIBUS (option)
240 to 750 Q (HART)
0.25
/2
F or less (HART)
Structure:
IP67 (NEMA 4X)
Housing:
Aluminum alloy
Coating:
Acrylic resin-baked coating, pearl-gray colored
Cable connection port:
1/2-14NPT thread
Cable glands not provided.
Arrester:
Arresters are installed in the power supply and current signal output circuit.
-
151
-