Toshiba – Toshiba LF600F User Manual
Page 57
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TOSHIBA
6,F,8,A0i8|6,9,
Key operation
Display example
Description
STEPS
A1:
EX CURRENT
0.21|0
Repeat this operation to change the setting value to
0.2150A.
[SEL]<=>[UP]
A
fU P] [SEL] fSETl
When the value changes to the desired value, press
the [SET] key to set the numeric value temporarily.
STEPS
A1:
EX CURRENT
0.2150
Pressing the [SET] key displays a message asking
you to confirm whether the setting is OK.
If OK, press the [SET] key. If you need to redo the
[SET]
A
OK?^
fNOl fSETl
setting, press the [NO] key.
STEP7-1
[NO]
A1:
EX CURRENT
B.1900
A
fU P] iSELl [SET]
Pressing the [No] key when you are asked "OK?"
causes the numeric value to return to the previous
value and enables you to redo the setting.
STEP7-2(=END)
A1:
EX CURRENT
0.2150
Pressing the [SET] key when you are asked "OK?"
causes the setting value to be determined.
Then if you press the [EXT] key, you return to the
[SET]
A
[EXTl [ENTl
menu screen.
If you press the [ENT] key, you can restart electric
current value change operation from a state of
0.2150A.
(Note) The exciting current value must be a value from O.OOOOA and 0.2500A.
If you set an exciting current value higher than 0.2500A, *HIGH OVER SPEC,* is displayed
and the set value is returned to the value before change. In this case you have to set a value
once again.
-