Key operation

Display example

Description

STEPS

A1:

EX CURRENT

0.21|0

Repeat this operation to change the setting value to

0.2150A.

[SEL]<=>[UP]

A

fU P] [SEL] fSETl

When the value changes to the desired value, press

the [SET] key to set the numeric value temporarily.

STEPS

A1:

EX CURRENT

0.2150

Pressing the [SET] key displays a message asking

you to confirm whether the setting is OK.

If OK, press the [SET] key. If you need to redo the

[SET]

A

OK?^

fNOl fSETl

setting, press the [NO] key.

STEP7-1

[NO]

A1:

EX CURRENT

B.1900

A

fU P] iSELl [SET]

Pressing the [No] key when you are asked "OK?"

causes the numeric value to return to the previous
value and enables you to redo the setting.

STEP7-2(=END)

A1:

EX CURRENT

0.2150

Pressing the [SET] key when you are asked "OK?"

causes the setting value to be determined.

Then if you press the [EXT] key, you return to the

[SET]

A

[EXTl [ENTl

menu screen.

If you press the [ENT] key, you can restart electric

current value change operation from a state of

0.2150A.

(Note) The exciting current value must be a value from O.OOOOA and 0.2500A.

If you set an exciting current value higher than 0.2500A, *HIGH OVER SPEC,* is displayed

and the set value is returned to the value before change. In this case you have to set a value