Appendix 3, Emc directive, Low voltage directive – Toshiba LF600F User Manual
Page 160: Toshiba
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

TOSHIBA
i6,F,8,A0,8,6,9,
Appendix 3
Electromagnetic Compatibility and Low Voltage Safety
LF600F and LF602F
electromagnetic flowmeter converter has been confirmed to comply with the
requirements of the EMC directive 89/336/EEC and the low voltage directive 93/68/EEC.
EMC directive
This device has been tested in a typical configuration in accordance with the following standards in an
industrial environment.
Generic emission standard
Conducted RF emissions
Radiated RF emissions
Generic immunity standard
Conducted RF immunity
Radiated RF immunity
Electrostatic discharge
Fast transient burst
EN50081-2
EN55011
EN55011
EN50082-2
ENV50141
ENY50140/ENV50204
EN61000-4-2
EN61000-4-4
The above EMC tests have been carried out with the flowmeter installed properly in accordance with
this instruction manual. However, there is no guarantee that interference will not occur in a particular
installation.
To reduce interference to or from other equipment, please check the following installation points.
(1) Use shielded cables for all I/O cables. When the flowmeter is the separated type, the signal cable
and excitation cable for the connection between the detector and the converter are supplied by
Toshiba. To improve immunity, pass each cable through a thick steel conduit tube.
(2) If this device is installed in an area where RFI exists, deviation of the current output signal may
be caused. In this case, ferrite cores will be required on each I/O cable. Please contact Toshiba or
the agency if required.
(3) This device is designed to be used in an industrial environment and may cause reception
interference to radio, television or wireless communications. In this case, relocate the receiving
antenna.
(4) The use of a transceiver or wireless equipment near this device may cause interference to the
accurate measurement. If deviation of the output signal appears during use of a radio, increase
the distance between the converter or the signal cable and the antenna.
Low voltage directive
Low voltage standards
EN61010-1
Environmental conditions:
Installation category
II
Pollution degree
2
Altitude
Up to 2000 m
Other conditions are specified in Chapter 15, “Specifications.”
-