TOSHIBA
¡6|F|8iA;0|8i6|9j
5.4 Wiring
IMPORTANT
The cable glands is not provided in the conduit port of this apparatus.
Please prepare yourself for the cable glands which could be used in Division2 hazardous locations.
A CAUTION
■ Do not wire cables and replace parts when
power is supplied.
Wiring work and
1
replacing parts in the
power-on state may cause
DON’T electric shock.
■ Do not work on piping and wiring with wet
hands.
Wet hands may result in electric
1
shock.
DON’T
5.4.1 Grounding
LF600F
(1) Grounding the LF600F type
Ground as shown in Figure 5.3. Make the grounding wire as short as possible. Use grounding wire
material of IV wire 5.5mm^ or more. Do not share a grounding wire with other instruments
where grounding current may flow. (An independent grounding is preferable.)
piping flange.
Figure 5.3 Grounding the LF600F Type
-
26
-