Bio-Rad BioLogic Signal Import Module (SIM) User Manual
Page 136

Table 7-1.
Valve Setup Information
MODES OF OPERATION
SYSTEM OPERATION
7-7
Notes
Functions as a fraction collection diverter,
determined by the actual fraction collection
parameters chosen.
When used before the inlet to Pump A or B, the
valve enables buffer selection. The buffer name
specified for each position will appear in the
Protocol screen’s “Isocratic Flow”, “Linear
Gradient”, and “Change Valve” dialog box. Refer
to Chapter 8, Sample Loading, for examples.
Used for auxiliary pump load selection to select
one of two solutions. Refer to Chapter 8, Sample
Loading, for examples.
When used for a purpose other than described
above. The name specified for each position will
appear in the Protocol screen’s “Change Valve”
dialog box.
When used before the inlet to Pump A or B, the
valve provides preparative sample loading or
buffer selection. The buffer or sample name
specified for each position will appear in the
Protocol screen’s “Isocratic Flow”, “Linear
Gradient”, and “Change Valve” dialog box. Refer
to Chapter 8, Sample Loading, for examples.
Used for auxiliary pump load selection to select
one of four solutions. Refer to Chapter 8, Sample
Loading, for examples.
When used for a purpose other than that
described above. The name specified for each
position will appear in the Protocol screen’s
“Change Valve” dialog box.
For automatically loading a sample.
When used for a purpose other than described
above. The name specified for each position will
appear in the Protocol screen’s “Change Valve”
dialog box. Refer to Section 4, Advanced System
Applications, Chapters 8 through 10.
Valve Type
Valve Name/
Position
Function
Names
SVT3-2
Fraction Collector
1 Waste
Low pressure
Diverter
2 Collect
solenoid valve
Note: Indicate
Inlet A
Named by user
the location
of the valve
Inlet B
Named by user
cable
connection.
When the
Maximizer is
Aux Pump Inlet
Named by user
used, inlets A
and B become
A1, A2, B1, B2.
User Assigned
Named by user
Name
SV5-4
Inlet A
Named by user
Low pressure
solenoid valve Inlet B
Named by user
Note: Indicate
the location
of the valve
cable
connection.
Aux Pump Inlet
Named by user
When the
Maximizer is
used, inlets A
User Assigned
Named by user
and B become Name
A1, A2, B1, B2.
AVR7-3
Sample Inject
1 Load Sample
High pressure
2 Inject Sample
valve
3 Purge
Note: Indicate
User Assigned
Named by user
the location
Name
of the valve
cable
connection
- BioLogic DuoFlow Pathfinder 80 System DuoFlow™ Chromatography System BioLogic DuoFlow Pathfinder 20 System DuoFlow™ Chromatography System BioLogic DuoFlow Maximizer 80 System DuoFlow™ Chromatography System BioLogic DuoFlow Maximizer 20 System DuoFlow™ Chromatography System BioLogic DuoFlow QuadTec 40 System DuoFlow™ Chromatography System BioLogic DuoFlow QuadTec 10 System DuoFlow™ Chromatography System BioLogic DuoFlow 40 System Chromatography System BioLogic DuoFlow 10 System Chromatography System