Figure 6-2. The CopyIn Window
CopyIn...
Allows you to copy in Methods and Runs from a backed-up or archived .ZIB file. Refer to
CopyOut page 6-3. To copy in:
a.
Press the CopyIn... button and select the .ZIB file you wish to copy in (Figure 6-2
above.)
b.
From the COPYIN List in the Browser Tab window, select the desired Methods and
Runs. All Methods and Runs in the file are displayed in the COPYIN List (Figure 6-3.)
c.
From the database tree window, click the left mouse button to select the Project to which
you want the Methods and Runs to be copied.
d.
Again, click on the CopyIn... button (or click on the right mouse button) and select Copy
to
button displays all the available Browser toolbar options for the highlighted selection.
e.
Once you finish the copy in procedure, use the Clear List button on the Browser tab
window to delete the methods and runs in the COPYIN List.
Default
08/04/97 11:55:34 AM
USER.............
Date...............
[00071]...........
Select All
Clear List
Select Copy In File
?
File name:
Folders:
biologic.zib
a:\
List Files of type:
a:\
Biologic Archive(*.ZIB)
Drives:
a:
biologic.zib
OK
Cancel
Help
Network...
...
Users.............1
...
...
...
....
Default.........................................................................................08/04/2001 11:55AM [1]
Default..................................................................................08/04/2001 11:55AM [0]
New...
Open...
Edit...
Delete...
CopyOut...
CopyIn...
Move
Reset
Queue
Compare
Information
MOVE List
QUEUES
COMPARE
COPYIN List
Error List
WL1 - 280nm
0.40
WL2 - 260nm
0.15
WL3 - 214nm
2.00
WL4 - 405nm
0.00
Flow Rate
EGP %B
0 %B
0.00 ml/min
0%
% Split
1.00ml/min
0 %B2
Maximizer + Gradient Pump: F10
UV
Conductivity
438 psi
1.003 AU
1.23 mS/cm
QuadTec
Econo Gradient
Pump
SIM1/pH
SIM1/SIG
0.548 Volt
7.00 pH
BioLogic Duo-Flow -
Edit
Method
New
Method
New
Run Browser
Manual Setup Protocol
wash
load
1
2
Run
Notes
Report
PostRun Log
Settings
File View Utilities Options Window Help
Name
Date
Bio-Rad
Web
INTRODUCTION TO THE BROWSER SCREEN
SYSTEM OPERATION
6-4
- BioLogic DuoFlow Pathfinder 80 System DuoFlow™ Chromatography System BioLogic DuoFlow Pathfinder 20 System DuoFlow™ Chromatography System BioLogic DuoFlow Maximizer 80 System DuoFlow™ Chromatography System BioLogic DuoFlow Maximizer 20 System DuoFlow™ Chromatography System BioLogic DuoFlow QuadTec 40 System DuoFlow™ Chromatography System BioLogic DuoFlow QuadTec 10 System DuoFlow™ Chromatography System BioLogic DuoFlow 40 System Chromatography System BioLogic DuoFlow 10 System Chromatography System