MTS Model FlexTest SE User Manual
Mts models flextest, Iim/gt/se controller hardware
This manual is related to the following products:
Table of contents
Document Outline
- Contents
- Technical Support
- Preface
- Introduction
- Installation
- Installing the Model 493.10 Chassis (FTGT)
- Installing the 493.02 Chassis (FlexTest SE)
- Installing 497/498 Electronics (FTIIm)
- Connecting the Console and Chassis Power
- Grounding the Console and Chassis
- Model 497.01 Analog Chassis
- Analog Chassis Transition Modules
- Adding an Analog Chassis to Your Console
- Model 497.05 Hydraulic Control Panel
- Test Processor Plug-in Modules
- Test Processor Transition Modules
- UPS Systems
- UPS Systems for FlexTest 60, 100, 200, and GT Controllers
- UPS Systems for FlexTest 40 and FlexTest SE Servocontrollers
- Specifications-UPS Systems Used with MTS Controllers
- UPS Connections for the Model 493.73 HPU Board (FT60, FT100, FT200, FTGT)
- UPS Connections for the Model 493.42 System board (FlexTest SE )
- FlexTest GT Controller Connections
- CE EMC Compliant Cabling
- Typical Cabling
- Cable Part Numbers
- Model 493.40 I/O Carrier Connections
- Sensor Cables
- Shunt Calibration/Bridge Completion Resistor Installation
- Transducer Identification Modules
- Valve Connections
- Multiple Universal Driver Connections
- Analog I/O Connections
- Accelerometer Connections
- Encoder Connections
- Remote Setpoint Adjust Connections
- ADDA II Connections
- Emergency Stop Connections
- J25 Hydraulic Power Unit Connection
- Station Connections
- Digital I/O Connections
- Workstation Connection
- Remote Station Controller Connection
- Service Connections
- Cabling and Programming Series 407 Controllers
- Connecting Interlock Signals to 458 Controllers
- Eurotherm Temperature Controller Connection
- Miscellaneous Conditioner Output Connections
- Cabling for External Command Inputs
- Cabling and Using External Readout Devices
- Multi-Box I/O Module
- FlexTest IIm Controller Connections
- Workstation Connection
- Sensor and Valve Connections
- ADDA Module Connections
- ADDA II Connections
- Hydraulic Connections
- HPU Connections
- Serial Communications
- Digital I/O Connections
- Encoder/Temposonics Connections
- Remote Station Controller (RSC) Connections
- Cabling and Programming External Controllers
- Cabling for External Command Inputs
- Cabling and Using External Readout Devices
- Cable Part Numbers
- FlexTest SE Controller Connections
- Hydraulic Configurations
- Model 493.07 Converter Box
- Chassis Maintenance
- Optional Station Configurations
- Index