J52 Box Out
Models FlexTest® IIm/GT/SE Controller Hardware
FlexTest SE Controller Connections
235
J52 Box Out
Connector J52 Box Out allows the Model 493.02 Chassis to send clock,
hydraulic, and interlock signals to another Model 493.02 Chassis.
Jumper plug required
If connector J52 Box Out is not used, you must install a jumper plug to maintain
the integrity of the interlocks. Use jumper plug PN 100-057-246 or jumper pins:
2-10, 3-11, 4-12, 5-13, 6-14, 7-15.
J52 Connector Pin Assignments
P
IN
N
AME
F
UNCTION
1
+clk in
+External clock output
2
hyd high out
Hydraulic high output
3
reset out
Interlock reset request output
4
ground
Signal ground
5
/intlk out
Hydraulic interlock output
6
hyd low out
Hydraulic low output
7
ground
Signal ground
8
N/C
No connection
9
- clk out
- External clock output
10
hyd hi return in
Hydraulic high return input
11
reset return in
Interlock reset return input
12
signal return
Signal return for optically isolated inputs
13
/intlk return in
Hydraulic interlock return input
14
hyd low return in
Hydraulic low return input
15
signal return
Signal return for optically isolated inputs