Cabling for External Command Inputs
Cabled properly, Model 793 Controllers can receive programming from an
external controller.
How to Enable and Run External Command Inputs
1. Cable the controllers.
Cable the external programmer analog out connector to a Model 493.75
Analog In module BNC connector.
2. Allocate external command resources in Station Builder.
Using Station Builder, allocate controller resources to receive programming
from an external controller.
3. Adjust the command signal with Station Manager.
4. Start the External Command.
External Analog Source
From
I/O Carrier
Module
FS
0
t
FS
0
t
0
t
Select Waveform
Generator
410.81
Function
Control Mode
Output Mode
Output
Remote Local
Local
Single
Cycle
Local
Start
Finish
Cycle
& Stop
Ret to
Zero
Trigger
Manual
Bkpt
Hold
Main
Sync
Output to 0
+100% FS
+100% FS
Breakpt
5 - 05%
Full Scale
Hold Time (sec)
Frequency (Hz)
Ramp Time 1 (sec)
Ramp Time 2 (sec)
FS
0
Normal
Invert