Connecting the Console and Chassis Power
Models FlexTest® IIm/GT/SE Controller Hardware
Installation
61
Installing 497/498 Electronics (FTIIm)
Contents
Connecting the Console and Chassis Power 61
Grounding the Console and Chassis 62
Model 497.01 Analog Chassis 63
Analog Chassis Plug-in Modules 64
Analog Chassis Transition Modules 66
Adding an Analog Chassis to Your Console 69
Model 497.05 Hydraulic Control Panel 71
Test Processor Plug-in Modules 72
Test Processor Transition Modules 74
Connecting the Console and Chassis Power
Each chassis installed in your console can be configured for 115 or 230 V AC
service. To configure each chassis for 230 V AC service, refer to the following
product manuals.
•
Model 497.05 Hydraulic Control Panel (100-036-577)
•
Model 497.01 Analog Chassis (100-036-577)
•
Model 498.22/498.23 Test Processor (100-036-578)—for FlexTest IIm
How To Connect the Chassis Power Cables
You can plug the hydraulic control panel and the test processor chassis into the
AC power strip inside the console.
The analog chassis requires an external power supply. Typically, it is connected
to the hydraulic control panel. If you have more than one analog chassis, you
must plug each additional analog chassis into a remote power supply.